ZoningSupply.com - Zone Control

HVAC Zone Controls & Zoning Dampers

durozone damper

More unbiased Zone control discusson on homeenergy

Other HVACzoning supplyComment

-------------------------------------------
QUESSTION by
Adam Zielinski

Homeowners with forced air duct systems always want to close the registers in rooms they aren't using, and close the doors to those rooms, in the belief that doing so will save energy and money.
I always thought doing this was over-rated and unlikely to save a significant amount of energy or money.  I could see doing it for one or two rooms perhaps, but sometimes homeowners close off half of their house or more.
This creates unbalanced air flow in the duct system and likely results in over heating the furnace heat exchanger, and or short cycling the furnace.  So the furnace spends a lot of time in start up mode and less time at peak efficiency.
I have not seen any real studies done on this however.  I'd like to see some data or research on this.

Reply by dale conner
Adam, most furnaces will move the proper amount of air through the blower and heat exchanger if the furnace cabinet pressure doesnt exceed .5 IWC and the furnace capacity was chosen based on a manual J calculation. This information can be found in the furnace installation manual or IOM (installation,operation,maintenance) that comes with a new furnace. However, this does not mean we are getting adequate air delivery to all of the rooms in the house due to excessive air leakage in the ducts and/or incorrect duct lengths or diameters routed to each room.

-----------------------------------------
QUESTION by Judi Lyall

How about using a motorized damper ?

Reply by dale conner
A single motorized damper can be used to control a zoned area but you also have to install a barometric by-pass damper to prevent over pressurization
www.zoningsupply.com

-----------------------------------------

See full discussion: http://homeenergypros.lbl.gov/group/hvac/forum/topic/show?id=6069565%3ATopic%3A7207

Damper Wiring: Yet another 5-terminal damper style wired to SmartZone

Supportzoning supply1 Comment

We confirmed today, thanks to a helpful customer, how another DuroZone damper wires using 3 wires (even though it has 5 terminals).

If your damper motors look like the one shown, wire to SmartZone as shown.

Another DuroZone model… on this model it is reported that some versions TERMINAL 4 (the blue wire shown) goes to CLOSE instead of OPEN.

If your motors looks different than this, see our other posts about damper wiring:
4-Terminal and 8-Terminal Damper Wiring

If the motors you have are not compatible with SmartZone, you still don't have to replace the whole damper.  You can replace just the motor (actuator) on just about any standard residential damper with the SmartZone / Belimo motor.

Power Open/Close Motor
from $69.99
w/ LEDs:
Quantity:
Add To Cart

SmartZone can be used with any 24V Damper

Supportzoning supplyComment
honeywell ard mard to smartzone wiring
smartzone to honeywell damper
smartzone durazone damper

There are many different models of 24VAC dampers available on the market.  Some have 2-wires, some have 3 wires, some have 5 wires and some even have 8 wire terminals.  Nearly all of these can be used with the SmartZone products (2L, 2X & 4X).  Both 2 and 3 wire dampers are straight-forward to wire and even shown in the installation guide that comes with SmartZone.  However, some of the less common types of dampers (4, 5, 6 & 8 wire) require a little more understanding.  How to wire some of them are shown below.

If you have any other type of damper, please contact us and we will help you.

 

Better dampers available from ZoningSupply:

PRO-Grade Power Zone Damper (Round)
from $64.99
Motor:
Diameter:
Quantity:
Add To Cart