De-humidification and SmartZone - Zone 1 Thermostat Control

HVAC Contractors, Other HVAC, Supportzoning supply1 Comment

Although SmartZone does not have any built-in capabilities for controlling DE-humidification (DH) or Humidification, some applications are possible by using a thermostat on ZONE 1 that does have the capability to control DH.

DE-humidification, in most residential systems, is simply running the equipment in COOLING with LOW speed fan instead of HI speed fan.

Before we get to zoning, the equipment being used must have the capability to control humidity.  This usually means it has a terminal (DH/BK/DS) that is energized or DE-energized by a thermostat to control fan speed of the equipment.  Controlling fan speed allows the equipment to DE-humidify the air when the fan is running in low speed.

Back to zoning, using zone 1 thermostat to control DH is not as simple as wiring directly from the thermostat to the equipment.  PLEASE DO NOT DO THIS.  The equipment and the zone thermostats are running on different transformers and this will case problems and potentially damage to some components.  You could isolate the output from the thermostat with a relay to get around this issue of different transformers but you would still have an issue with this method of wiring "around" the zone controller.  The issue can arise when zone 1 calls for DH but the equipment is already running in heat, this mixed signal might just be ignored by the equipment but we cannot take that for granted... all equipment works differently.

ecojay smartzone de-hum using y2 -BASIC.JPG

The best way to control DH using SmartZone on single stage equipment is by using the method below.  It may seem a little UN-orthidoxed but it is a valid APP note from the engineer at Ecojay (It's intended to work this way).

  1. Select a DH enabled thermostat of your choice
  2. Connect Y2/ECO on SmartZone Zone 1 to Zone 1 Thermostat DH/DS/BK
  3. Connect Y2 on SmartZone Equipment toEquipment DH/DS/BK
  4. Set Zone 1 "STAT TYPE" to G2
  5. Set DIP switch #4 to "LOCKOUT"

Zone 1 thermostat will now enable and disable DE-humidification any time the equipment is running in the cooling mode.
NOTE: When starting cooling from OFF state, 90 second delay will occur before HIGH speed fan will energize.

Using this method we are assuming that the equipment is expecting DS/BK/DH input terminal to be ENERGIZED for high speed fan and DE-ENERGIZED for low speed fan.  This method should not be used for more than 3 zones or with multi-stage compressor equipment.


SmartZone-2X
Sale Price:$159.99 Original Price:$199.00
Quantity:
Add To Cart
 

This application will work with Ecojay's SmartZone-2X and SmartZone-4X.  Learn more

Click for SmartZone-2X/4X Install Guide

Click for SmartZone-2X/4X Install Guide

Need more than 40VA to power LOTs of dampers on one SmartZone?

HVAC Contractors, Supportzoning supplyComment

Some systems with many small ducts leading to each zone can require lots of dampers.  The example below is a 2 zone system that requires 6 dampers per zone (12 total).  If you look at the zoning guide, you will find that you should budget for at least 55VA for this system... but you only have 40 VA transformers.  75 and 100 VA transformers can get VERY expensive!  Instead you can use two 40VA transformers, but not how you think.  It can be dangerous and unreliable to connect transformers in parallel to create ~80VA.  We recommend the method below that employs the use of a simple relay to separate half of the dampers to be powered from a second transformer and the other half being powered by the SmartZone and it's transformer.

See the SmartZone Install Guide to calculate required VA.

It is always necessary to verify that the PRIMARY side power is sufficient to power the transformer connected.  A dedicated PRIMARY circuit is best but not always possible.  If sharing the 110V or 220V circuit, make sure the total power required for all devices connected (including zoning transformers) doesn't exceed the capacity of the circuit (usually 15 or 20 AMPS).

Where to get a relay?
Any 24V relay with a DPST or DPDT configuration will work.  The one pictured in the above diagram is available at ZoningSupply.com (see below).   If you are chosing your own relay, the "Contact" current rating will determine how many dampers can be connected.  (For example: A 10 Amp relay can handle up to 10 power open, power closed dampers)

24V Relay - DPDT
$14.99
Quantity:
Add To Cart
 
Power Open/Close Motor
from $69.99
w/ LEDs:
Quantity:
Add To Cart

Honeywell TrueZone ARD Dampers wiring to SmartZone

Supportzoning supplyComment

The latest form Honeywell ARD dampers is a nice looking product and works nicely with ecojay SmartZone.  Wire as shown below.  Other damper wiring at www.zoningsupply.com/blog


SmartZone-4X
Sale Price:$229.99 Original Price:$299.00
Quantity:
Add To Cart
PRO-Grade Power Zone Damper (Round)
from $99.99
Diameter:
Quantity:
Add To Cart

SmartZone has the simplest setup and best features of any zone control. Find out more about SmartZone and why it's the smart choice: www.zoningsupply.com/buy-smartzone/

Damper Wiring: Yet another 5-terminal damper style wired to SmartZone

Supportzoning supply1 Comment

We confirmed today, thanks to a helpful customer, how another DuroZone damper wires using 3 wires (even though it has 5 terminals).

If your damper motors look like the one shown, wire to SmartZone as shown.

Another DuroZone model… on this model it is reported that some versions TERMINAL 4 (the blue wire shown) goes to CLOSE instead of OPEN.

If your motors looks different than this, see our other posts about damper wiring:
4-Terminal and 8-Terminal Damper Wiring