ZoningSupply.com - Zone Control

HVAC Zone Controls & Zoning Dampers

HVAC Contractors,Other HVAC

NEW Product: Stand Alone Damper Control using ANY Thermostat

thermostats, Products, HVAC Contractorszoning supplyComment

Sometimes, full blown zone controls are not needed to solve an airflow or temperature related issue in the ducting of a home or other building.

One example might be a bonus room, a basement or a 3 season room that could benefit from some air occasionally but doesn’t necessitate a zone control system with all of the features included with our SmartZone products.

For these applications, we have developed a control board that can connect a thermostat directly to a damper for basic control.

With this Damper Direct Controller, you can simply connect any thermostat, a 24vac transformer & hook up your damper (ANY damper will work as long as it is 24V).

The applications for this product are too may to list but, for us, it is just one additional tool in the toolbox for managing comfort and efficiency of your home or building’s HVAC. Contact ecojay.com or us here at ZoningSupply if you have any questions or ideas.

Direct Damper Controller
Sale Price:$39.99 Original Price:$49.99

FRESH AIR - SmartZone Automatic Contrtol with RANCO ETC Outdoor Temperature Sensor

Other HVACzoning supply10 Comments

Fresh Air is important to indoor air quality (IAQ). All the way back to Benjamin Franklin’s “air baths” and even much earlier in history, we have had some at least vague understanding of the fact that “stale” indoor air can be bad for us and we need to get some fresh air at least once in a while.

In modern homes, windows, doors, insulation , house wraps, roofing and other materials have imporved drastically in the last 40 years and we how have homes and buildings that are getting tighter and tighter. This means that the air outside stays out and the air inside stays in... which is good for efficiency of heating and cooling systems, but not for air quality and overall health. This is why many parts of the world have “fresh air” requirements, meaning simply that they are required to bring in a prescribed amount of outside air in and mix it with the inside air. In the US, a standard callled ASHRAE 62.2 is followed as a guideline for how much outside air in CFM (Cubic Feet per Minute) needs to be brought in based on occupancy & square footage of the home/building. We are not here to discuss the efficacy of the 62.2 because it has some obvious flaws in its sheer simplicity, we just want to show how to apply this method of fresh air but with one additional VERY IMPORTANT feature. We want to simply disable the automatic intake of outside air WHEN the outside temperature is too high or too low. What is too high or too low? This is going to depend on your application including climate, hvac equipment type, home size, your comfort level etc.

NOW AVAILABLE - Ecojay custom Outdoor Temperature Controller

The use of the RANCO temperature controller is no longer necessary with the SmartZone. We now offer a custom outdoor temperature controller that provides MUCH more functionality specific to the SmartZone Fresh Air controls.

  • High & Low Temperature Limits

  • Enable/Disable Fresh Air

  • “Demand” Fresh Air

  • NEW: Temperature-based Economizer

For more info about this new and exiting product, take a look here:
https://zoningsupply.com/buy/outdoor-air-thermostat

If you are considering Fresh Air or Economizer with your SmartZone-4X, you will want this accessory!

The primary reason for this “ADVANCED FEATURE” is to prevent outside air that is extreemly hot or cold from coming into the house automatically. Use the instructions and diagrams below to install this RANCO ETC-212000 Temperature sensor and you will have the ability to control automatically the temperature range that Fresh Air is allowed to operate. For example , you could set the upper limit to 90 deg F and the lower limit to 30 deg F and then SmartZone will only operate fresh air when the outside temperature is between 30 and 90 deg.

RANCO with SmartZone

Before this Outdoor Temperature Advanced Fresh Air Feature will work, the SmartZone-4X must be set up for FRESH AIR control. Click the button below to see an application note about basic fresh air. NOTE: Fresh-Air setup instructions can also be found in the SmartZone System Guide

Fresh Air for better Indoor Air Quality

Other HVACzoning supply5 Comments

When people think about increasing the Indoor Air Quality of their homes, most probably think about pollutants like smoke/smog or allergens like pollen. Since these originate “outdoors”, the most logical thought is to close up your home as tight as possible and get an air cleaner of some sort. Although air cleaners like filters can and do help reduce the particles in the air to a varying degree, there is MORE to AIR quality than just “cleaning” the air.

The most critical and often overlooked aspect of having good indoor air quality is FRESH AIR. This, in it’s simplest form, is bringing outside air … inside. The first thought of objection might be that it seems counter-intuitive to bring air in that could have pollutants to try and “clean” the air, however, the EPA and other independant studies by AHRAE have shown that the pollutants like pollen can be 2 or 3x as high as outside air if a home is not properly ventilated. (see link below for sources and further explanation)

EPA recommendations for improving Indoor Air Quality: https://www.epa.gov/indoor-air-quality-iaq/improving-indoor-air-quality

A “properly ventilated” house includes both the intake of fresh air and the exhaust of inside air. Most homes come equipped with plenty of exhaust either in the bathrooms or kitchen vent hood but many do not have nearly enough intake of outside air. As a matter of fact, up until the 2000s, most homes were not equipped with any Fresh Air management at all which means that the only outside air that was coming inside was through cracks around doors and window. You might think this was an accident but it was actually “designed” this way because it has been know for 100 plus years that outside air is necessary for a healthy and clean air environment.

SmartZone-4X has a built-in FRESH AIR controller, that can be used to automatically (or manually) bring fresh air into the building. It was designed as a feature to meet the ASHRAE 62.2 standard but has many additional and useful features that make it more desirable than a standard “Fresh Air Control” like the Honeywell W8150.

Shown below, the SmartZone can be used as a “stand-alone” fresh air controller even without the need for any zoning.

Find out more and learn about the Adavanced Fresh Air control features: FRESH AIR - Enthalpy Control

Buy SmartZone-4X for your Fresh Air control

What's a TON got to do with AC?

homeowners, Other HVACzoning supply2 Comments

So you've probably heard of someone refer to an air conditioner's size in terms of  "TONS".  Something like "I got a new 4 TON HVAC unit".  This refers, not to physical size, but to the capacity (ability) of the equipment to generate heat.  That's right, even air conditioning (cooling), is sized by it's ability to produce heat.  In the case of air conditioning, the heat is being "pulled" from inside the house and dispersed outside.  This is why there is always an outdoor component (the air conditioning compressor) when you have AC.

Back to TONs... most people thing of a TON as being 2000 lbs. but with regard to HVAC, a TON is a measurement of heat generation per day.

1 TON of air conditioning is a measure equivalent to the amount of heat necessary to melt 2000 lbs of ice (H20) in a 24 hour period.

ecojaytonexplain1.jpg

But how did we get there? A BTU (British Thermal Unit) is the unit we use express heat energy.  One BTU is equivalent to the amount of heat energy released when burning 1 match all the way. When rating an HVAC unit either for heating or cooling, the amount of BTUs per Hour is often sited.  It has been measured that it takes 143 BTUs to melt 1 lb of ice.  Since, 1 TON of ice is 2000lbs, It will take 2000 x 143 = 286,000 BTUs to melt 1 TON of ice.  The ice could be melted by lighting 286,000 matches all at once or by lighting one at a time... In other words, BTUs only tells us how much heat energy is necessary but not over what time period.  It could melt in 1 minute, 1 hour, or even 1 year depending on how the energy is generated.  So, to rate the output of HVAC equipment, someone decided back in the early 1900s (probably someone at Carrier) that it should be done over a 24 HR peroid (1 day).  This is how we get 286,000 BTUs / 24 hrs =~ 11,917 BTUs per hour or commonly know as 12K BTU/hr is equal to 1 TON.

ecojaytonexplain2.jpg

This means that that 4 TON AC unit you have can melt 8,000 lbs of ICE per day or about the same size block of ice as a Suburban.  That's a lot of heat energy!

ADD-A-WIRE with Zone Control

HVAC Contractors, homeowners, Other HVACzoning supplyComment

An ADD-A-WIRE device can be used when upgrading to thermostats that need a "COMMON" wire from one that didn't have one... and there is no way to run the additional wire needed.  This device, ranging from $15 to $40 can come in very handy especially in the case of zone control where one or more thermostat does not have enough wires to accomodate a modern thermostat such as a WiFi thermostat.

Be sure to follow the wiring diagram for the specific model of "ADD-A-WIRE" as well as the system type.  Show here is the LUX Products LPB-WH Power Bridge wired to a GAS/ELECTRIC thermostat and SmartZone-4X controller, however, the basic principal is the same for any application.

lux addawire instructions.jpg

All of the different ADD-A-WIRE models come with instructions, read them carefully and follow exactly and you won't have any problems.

For more information about the method of ADD-A-WIRE when there is no way to run an extra wire from your zone panel to your equipment, check out this post:
https://zoningsupply.com/blog/upgrading-thermostats-solving-a-common-problem

From an engineering perspective this is an elegant and simple solution.  Without giving away trade secrets, the ones i have tested use the a half wave bridge using diodes at the thermostat and some simple relay logic plus the another half wave at the equipment (no micro necessary) to use only 1 wire for both Y and G signals.... brilliant.

For more information, or with any questions, please contact us.

Upgrading thermostats; solving a "common" problem

HVAC Contractors, Support, homeownerszoning supply1 Comment

So, maybe you have decided to upgrade to a Wifi thermostat, or even just a standard "programmable" thermostat... only, you come to discover that your old thermostat has one less wire connected to it than the new thermostat needs.   This is usually the "24VAC Common" wire sometimes just called "C" or "24C".   This means that your old thermostat was either mechanical, power stealing, or battery operated... which isn't a problem if you don't want a modern thermostat.  MOST modern thermostats (especially WiFi) need a "C" wire from the 24V transformer to power the thermostat... this means getting a "C" wire to the thermostat.

This isn't a new problem, it started showing up in the 1980s with the first programmable thermostats... over the years, I have suggested and used several different methods to overcome this issue both with zoning and with typical single thermostat applications.  Until recently, I couldn't really recommend anything other than running a new wire... and running a new wire isn't always possible.

METHODS to add "C" Wire

  1. Run another wire to the thermostat
    The most straightforward and full-proof method is obvious: run another wire.  If possible, this is ALWAYS your best solution.
  2. Power thermostat from separate transformer
    Don't use this method... it is risky and not all thermostats support the ability to separate the "R" from the equipment transformer.
  3. Use the "G" wire for "C"
    This method DOES work but it limits the functionality of your thermostat control.  (ie. you will not be able to independently control fan from the thermostat)  The reason this works, is that the equipment automatically turns the fan on during a heating or cooling call, so the "G" wire controlling the fan from the thermostat is only necessary to turn the fan on by itself.  You will NOT be able to turn fan on from the thermostat by itself with this method.
    NOTE: This works with MOST equipment, but you should check or test before employing this method. (#3)
  4. ADD-A-WIRE Device
    It is the BEST method and really the only method I would use if a wire cannot be run.  This is a relatively new concept to me... it has been around for a few years at least but we just started recommending it within the last 2 years.    Several companies have started offering an "ADD-A-WIRE" device that allows the addition of a "COMMON" wire.  These devices range from $15 - $40 and are very simple to wire (you have to be able to get to your equipment furnace/blower). 
lux addawire.JPG

How an ADD-A-WIRE Device works:

venstar addawire.JPG

It will come in 2 pieces, one is a small box with several connections labled "R", "C", "Y", "G", "W".  You will follow the included wiring instructions to connect this box at your indoor HVAC equipment.  The other piece that comes with the ADD-A-WIRE is a wiring connector with 3 leads, this connects at the back of your thermostat as shown in the wiring instructions.
Once these two pieces are wired properly you will have the "C" you need for any thermostat... it's almost like magic (electrical engineering magic).

NOTE: Make sure all wiring is done with the power to the HVAC equipment OFF at the breaker.

A few different models to choose from (prices on amazon at time of writing)  There are many others available but they all do the same thing (NOTE: we are not compensated by any of these companies or any others for our opinions):

For more information about specific use with zoning and zone control systems such as SmartZone... contact us

Another thing to consider:  The ecobee3 and ecobee3 LITE both come with an "ADD-A-WIRE" type device.  So, if you are thinking about a WiFi thermostat and are afraid you will need to add a wire... keep the ecobee in mind.  See our WiFi stat roundup for more info

De-humidification and SmartZone - Zone 1 Thermostat Control

HVAC Contractors, Other HVAC, Supportzoning supply1 Comment

Although SmartZone does not have any built-in capabilities for controlling DE-humidification (DH) or Humidification, some applications are possible by using a thermostat on ZONE 1 that does have the capability to control DH.

DE-humidification, in most residential systems, is simply running the equipment in COOLING with LOW speed fan instead of HI speed fan.

Before we get to zoning, the equipment being used must have the capability to control humidity.  This usually means it has a terminal (DH/BK/DS) that is energized or DE-energized by a thermostat to control fan speed of the equipment.  Controlling fan speed allows the equipment to DE-humidify the air when the fan is running in low speed.

Back to zoning, using zone 1 thermostat to control DH is not as simple as wiring directly from the thermostat to the equipment.  PLEASE DO NOT DO THIS.  The equipment and the zone thermostats are running on different transformers and this will case problems and potentially damage to some components.  You could isolate the output from the thermostat with a relay to get around this issue of different transformers but you would still have an issue with this method of wiring "around" the zone controller.  The issue can arise when zone 1 calls for DH but the equipment is already running in heat, this mixed signal might just be ignored by the equipment but we cannot take that for granted... all equipment works differently.

ecojay smartzone de-hum using y2 -BASIC.JPG

The best way to control DH using SmartZone on single stage equipment is by using the method below.  It may seem a little UN-orthidoxed but it is a valid APP note from the engineer at Ecojay (It's intended to work this way).

  1. Select a DH enabled thermostat of your choice
  2. Connect Y2/ECO on SmartZone Zone 1 to Zone 1 Thermostat DH/DS/BK
  3. Connect Y2 on SmartZone Equipment toEquipment DH/DS/BK
  4. Set Zone 1 "STAT TYPE" to G2
  5. Set DIP switch #4 to "LOCKOUT"

Zone 1 thermostat will now enable and disable DE-humidification any time the equipment is running in the cooling mode.
NOTE: When starting cooling from OFF state, 90 second delay will occur before HIGH speed fan will energize.

Using this method we are assuming that the equipment is expecting DS/BK/DH input terminal to be ENERGIZED for high speed fan and DE-ENERGIZED for low speed fan.  This method should not be used for more than 3 zones or with multi-stage compressor equipment.


SmartZone-2X
Sale Price:$159.99 Original Price:$199.00
Quantity:
Add To Cart
 

This application will work with Ecojay's SmartZone-2X and SmartZone-4X.  Learn more

Click for SmartZone-2X/4X Install Guide

Click for SmartZone-2X/4X Install Guide

MEP Drawings & Specs for Generic HVAC Zone Control System

HVAC Contractors, HVAC Industry, Zone Control Infozoning supplyComment

Typical wording for HVAC Mechanical drawings to include SmartZone Zone control (2 to 8 zones):

ECOJAY SMARTZONE ZS2X (2 ZONES) OR ZS4X (UP TO 4 TO 8 ZONES)

1. SMARTZONE CONTROLLER SHALL INCLUDE FLASH BASED MICROPROCESSOR FOR AUTOMATIC CONTROL OF UP TO 2 ZONES (ZS2X), 4 ZONES (ZS4X) OR 8 ZONES (TWO-ZS4X CONTROLLERS) ON A SINGLE HVAC SYSTEM.

2. SMARTZONE CONTROLLER SHALL INCLUDE LED DISPLAY WITH FULL TEXT STATUS
MONITORING AND DIAGNOSIS OF THE ENTIRE SYSTEM STATUS AND SUPPLY TEMPERATURE.

3. SMARTZONE CONTROLLER SHALL CONTAIN ELECTRONIC LIMIT CONTROL (ELC) SUPPLY AIR SENSOR WHICH ALLOWS CONSTANT MONITORING OF THE LEAVING (SUPPLY) AIR TEMPERATURE

5. PUSH BUTTONS SHALL ALLOW FOR DIGITAL ADJUSTMENT OF HIGH AND LOW LIMIT

4. IN THE EVENT OF SUPPLY AIR SENSOR OR SENSOR WIRING FAILURE, THE CONTROLLER SHALL CONTINUE OPERATING THE HVAC SYSTEM AS A SINGLE ZONE SYSTEM WITHOUT INTERRUPTION

6. ON HEAT PUMPS SYSTEMS, EMERGENCY HEAT MUST BE INITIATED FROM THERMOSTAT #1, NOT A SWITCH ON THE ZONE CONTROL BOARD.

7. EACH ZONE CONTROLLER THERMOSTAT TERMINAL AND EQUIPMENT TERMINAL SHALL HAVE A COLOR-CODED LED ALLOWING FOR EASY MONITORING OF THERMOSTATS AND SYSTEM CALLS.

8. ROUND ZONE DAMPER MOTORS SHALL BE 2-POSITION (OPEN/CLOSE) DESIGN WITH A SOFT-EDGE BLADE DAMPER SIZE AS ROUND DUCT IN WHICH BLADE GASKET AND SHALL BE POWERED BY 24VAC POWER OPEN / POWER CLOSE MOTOR DEVELOPING MINIMUM 10 IN-LB. OF TORQUE AT MAX 4 VA

9. RECTANGULAR ZONE DAMPER MOTORS SHALL BE 2-POSITION (OPEN/CLOSE) DESIGN WITH EXTRUDED ALUMINUM FRAME & LOUVERS & METAL SHAFT LINKAGES AND SHALL BE POWERED BY 24VAC POWER OPEN / POWER CLOSE MOTOR DEVELOPING MINIMUM 10 IN-LB. OF TORQUE AT MAX 4 VA

10. ALL ZONE DAMPERS SHALL INCLUDE ACCURATE, NON-ADJUSTABLE & ADJUSTABLE, BLADE POSITION INDICATOR AND ADJUSTABLE MINIMUM STOP CAPABILITY (MIN OPEN & MIN CLOSE).

11. AUTOMATIC, ELECTRONIC BYPASS DAMPER WITH STATIC PRESSURE CONTROL IS REQUIRED WITH 24V ELECTRIC ACTUATORS UNLESS NOTED OTHERWISE.

12. ZONE CONTROLLER, DAMPER MOTORS AND THERMOSTATS SHALL BE POWERED WITH A SEPARATE 24V FUSED TRANSFORMER (TYPICALLY 40VA) PROVIDED BY HVAC CONTRACTOR.

13. CONTACT ECOJAY.COM or 1-888-523-ECOJAY FOR MORE INFORMATION OR TRAINING

WiFi Thermostat Roundup 2017

homeowners, Other HVAC, thermostatszoning supplyComment

Just a few short years ago, WiFi thermostats were only made by a very few companies starting with Ecobee and RadioThermostat, followed by Nest.  A couple of years pass and big names in the HVAC industry (Honeywell, Emerson, Venstar, etc) join the WiFi thermostat party.  In 2017 we have more to chose from than can easily be kept up with.  Note: All prices as of this article publish date.

All of the WiFi thermostats listed below will work with any SmartZone

I am sure there will be even more on the market in 2018, we will keep watching the WiFi thermostat bubble grow!  More than 15 are listed here (and I know they are not all listed).  If you know of any more, comment or tweet to us @zoning_supply


wifi stat - bosch connected.JPG

Bosch - $ 170, 4-Heat, 2-Cool, GE/HP, Hum, deHum, Color: White
https://www.amazon.com/dp/B073XHD8BB



TOP PICK

*Ecobee 3 - $ 169, 3-Heat, 2-Cool, Best for zoning in our opinion.
https://www.amazon.com/ecobee3-Smart-Thermostat-Works-Amazon/dp/B06W56TBLN/


wifi stat - ecobee4 w Alexa.JPG

PREMIUM CHOICE

Ecobee 4 - $ 247, 3-Heat, 2-Cool, Alexa-Enabled
https://www.amazon.com/ecobee4-Alexa-Enabled-Thermostat-Sensor-Amazon/dp/B06W2LQY6L/


wifi stat - emerson sensi color.JPG

Emerson Sensi Color Touch - $ 169, 2 Heat, 2 Cool, GE/HP
https://www.amazon.com/dp/B01N3CEUDH?psc=1


Emerson Sensi - $ 99, 1 Heat, 1 Cool, GE/HP
https://www.amazon.com/dp/B00HHE6CW2?psc=1


wifi stat - nest.JPG

Nest - $ 249, 3-Heat, 2-Cool
https://www.amazon.com/dp/B0131RG6VK/





wifi stat -Honeywell 7-day.JPG

Honeywell Basic 7-day - $ 90, 1-Heat, 1-Cool, GE, Color: White (Yes this is WiFi--even though it doesn't look like anything other than an inexpensive thermostat)
https://www.amazon.com/dp/B00Y6M2OUC/




wifi stat - Lux Pro Black.JPG
wifi stat - Lux Pro.JPG

VALUE CHOICE #1

Lux PRO GEO - $ 115, Geofencing, Mount Vertical or Horizontal, Color: Black or White
https://www.amazon.com/Lux-Products-GEO-WH-Thermostat-Amazon/dp/B010PTKWW6/


wifi stat - RadioThermostat.JPG

RadioThermostat - $ 99, 2-Heat, 2-Cool, GE/HP, Modules for Zigbee & Z-Wave
https://www.amazon.com/Radio-Thermostat-Programmable-Enabled-Controls/dp/B00KQS35XA/


wifi stat - Vine.JPG

VALUE CHOICE #2

*Vine - $ 99, Settings Knob, Color Screen & Night-Light
https://www.amazon.com/Vine-Programmable-Thermostat-Touchscreen-Nightlight/dp/B01JU1DZN8/



Any information in this article should be verified with the manufacturer of each product listed.  Specifications, prices & availability are all subject to change and will not be kept current on this post.  Please email us if you have any questions.

ALSO NOTE:  We (I) have not been paid or compensated in any way for this article by any of the manufacturers of these products.  I have not even received any free product... anything reviewed has been purchased through retail outlets and tested with SmartZone zone control products for the use of ZoningSupply.com customers.  This information is not intended to be exhaustive or claim expert knowledge about all of these thermostats.  Thank you.

Need more than 40VA to power LOTs of dampers on one SmartZone?

HVAC Contractors, Supportzoning supplyComment

Some systems with many small ducts leading to each zone can require lots of dampers.  The example below is a 2 zone system that requires 6 dampers per zone (12 total).  If you look at the zoning guide, you will find that you should budget for at least 55VA for this system... but you only have 40 VA transformers.  75 and 100 VA transformers can get VERY expensive!  Instead you can use two 40VA transformers, but not how you think.  It can be dangerous and unreliable to connect transformers in parallel to create ~80VA.  We recommend the method below that employs the use of a simple relay to separate half of the dampers to be powered from a second transformer and the other half being powered by the SmartZone and it's transformer.

See the SmartZone Install Guide to calculate required VA.

It is always necessary to verify that the PRIMARY side power is sufficient to power the transformer connected.  A dedicated PRIMARY circuit is best but not always possible.  If sharing the 110V or 220V circuit, make sure the total power required for all devices connected (including zoning transformers) doesn't exceed the capacity of the circuit (usually 15 or 20 AMPS).

Where to get a relay?
Any 24V relay with a DPST or DPDT configuration will work.  The one pictured in the above diagram is available at ZoningSupply.com (see below).   If you are chosing your own relay, the "Contact" current rating will determine how many dampers can be connected.  (For example: A 10 Amp relay can handle up to 10 power open, power closed dampers)

24V Relay - DPDT
$14.99
Quantity:
Add To Cart
 
Power Open/Close Motor
from $69.99
w/ LEDs:
Quantity:
Add To Cart

New & Improved Rectangle Dampers available at ZoningSupply.com

Products, HVAC Contractors, ZoningSupplyzoning supplyComment

Tired of flimsy residential-grade rectangular dampers that easily bend and bind and, worse yet, stop working prematurely.  We, at ZoningSupply, are too!  And, we have the answer with this commercial-grade, super-duty rectangular damper.  Like all of our power dampers, it includes the best motor in the industry (Belimo) and now is constructed with heavy guage aluminim for rigidity and long-life.

Heavy-Duty

Rectangle Damper

Rectangular HVAC Dampers
from $199.99

6" X 6" thru 24" X 24"
SUPER Heavy-Duty
Aluminum rectangular damper w/ Ecojay by Belimo motor
Built to stand up to use and abuse

ATTENTION:

Due to delays receiving raw materials, the shipping time on these custom rectangular dampers has been extended: UP TO 3 or 4 WEEKS

We are very sorry about this delay and will be back to normal shipping times by the end of the year. Please call us if you have any questions or concerns about your order.

SPEC SHEET

SHIPPING TIME: UP TO 3 or 4 Weeks

(because they are custom made to order)
RETURNS for rectangular dampers require 25% restocking fee because they are custom made to order... please be sure you order the correct size.

NOTE: The motor will always be mounted on the “HEIGHT” side

Height:
Width:
Quantity:
Add To Cart

No other rectangle zone damper on the market is as sturdy or reliable.  Simplicity of design and precision manufacturing in the USA (Ohio & Texas) make for the BEST rectangular damper that has ever been available to the residential zone control market.  Try it for yourself today.

Ashrae 62-2 Ventilation (Fresh Air) sizing & calculation

HVAC Contractors, Support, Other HVACzoning supplyComment

Many homes these days have such tight seals around doors, windows, and even closed-cell foam insulation... they are almost air-tight.  You can think of an old house like an antique metal or wooden ice box where modern homes are more like Yeti coolers.  While this is great for keeping temperatures steady inside the home, it also can trap moisture and toxic gases inside.  Fresh air ventilation is necessary to keep a healthy and efficient home.

But how much fresh air is needed?  If you bring in too much, you will make your HVAC equipment work too hard and loose efficiency.  If not enough fresh air is brought into the home, the air can become humid and allow mold growth or VOCs and other toxins can build up.  Luckily, the national organization ASHRAE has a specific recommendation for the amount of air based on occupancy and square footage of the home.  See table below.

However, this table should not be taken as gospel.  Just like other HVAC calculations and estimations, many factors are not really being taken into account with this rough estimate based on # of bedrooms (occupancy) and square footage.  Some adjustments may be needed based on factors such as climate, ceiling height, other air-leakage, etc.  To comply with 62-2 is the baseline & adjustments can be made in the field by setting run-time.

Learn more about how SmartZone-4X can control fresh air more efficiently than a separate fresh-air controller in the Install Guide

SmartZone is great opportunity for DISTRIBUTORS.

Other HVAC, HVAC Industryzoning supply2 Comments

There are many reasons that distributors should take a look at stocking SmartZone, but basically because they can make more money & have a higher customer satisfaction with a very low up-front investment.

  1. Only 2 models needed to cover all applications.
    A lot of manufacturers require stocking 5,6... even dozens of different products to get the best price.  With SmartZone, you only need the SmartZone-2 and the SmartZone-4X.  That's right, only 2 models will cover everything from 2 zones to 20 zones, single & multi-stage, gas/electric & heat pump (including dual fuel).  As a bonus, the SmartZone-4X has built-in Fresh-Air control.
     
  2. Best wholesale pricing.
    Options for small and large volume distributors with 30 day NET terms pending credit approval.  Start with a small order or only 10 zone controllers.  Contact ECOJAY (www.smartzoning.com) for details.
     
  3. Documentation & training.
    Ecojay is committed to supporting distributors with documentation, signs, marketing materials, phone & online support.  Ecojay will even do an in-person training for contractors at new distributor locations (minimum order required for free training - normal price for training $500)
     
  4. Increase zone control profits & sales.
    SmartZone has allowed many of our distributors to increase sales of zoning because it is so much easier for contractors to use & install... they buy more.  Distributors of SmartZone also have increased margins on the higher-end controllers because SmartZone-4X can do everything the Honeywell HZ432 can do at a much lower price.
     
  5. Contractors will love you for it.
    Even contractors that "don't do zoning" occasionally come across a system that needs it or a customer that wants it.  SmartZone is the best the the occasional zoning contractor or the contractor that does it every day.  Most contractors that try it, don't want to use anything else.


Right now, only about 25-35% of the US has physical distribution of ECOJAY products, specifically SmartZone.  This is a HUGE missed opportunity.  Online distribution reaches nationwide, but even this is in it's infancy.  SmartZone deserves to be on the shelf of your local distributor and contractors deserve to have access to it.  Right now it is available on Amazon.com, Ebay, ZoningSupply.com for contractors in the US & Canada to have in a couple of days shipping time.

It would be great if some of the large online supply houses like ... Supplyhouse.com or AlpineAir.com would stock SmartZone so it could be purchased and shipped along with systems.  Or some of the national-chain distributors like Johnstone would also carry SmartZone for the sake of availability and exposure to SmartZone style zoning.

SmartZone is not a new gimmic in zoning, it is simply the BEST traditional forced-air zone control board that is available.  SmartZone has been designed with the HVAC contractor in mind and it shows with the feedback that is received over and over again from contractors.  SmartZone has been shipping since 2004 and has had rave reviews from the beginning. 

Contractors that never liked zoning before even love SmartZone.  Many of the problems that people had 10 or 15 years ago with zoning such as freezing coils or short cycling have been solved by more sophisticated zone controls but SmartZone made it simple.  Using Ecojay SmartZone makes zoning simple.

 

Fact or Myth? #HVAC #Zonecontrol can save energy

homeowners, HVAC Contractorszoning supplyComment
SmartZone zone control

First of all, if you are not familiar with HVAC Zoning (Zone control) for your home you can click here and learn more about how it works.

Sometimes, zoning is pitched as a device that can be added to your current HVAC system that will "save you energy" because you are able to turn "off" heating and cooling to areas that are not being used.  Sounds good, right?  Well...there a "but."  This as actually a highly debated or more aptly put... highly contested claim among HVAC professionals.

The simple fact is that it isn't a simple answer but the simplest version is:  HVAC Zoning CAN save energy in some applications.

Not all applications of zoning are intended to save energy, some are set up to optimize comfort.  In these situations, energy savings may not the top priority but it can still be set up to help save energy when the comfort is not in demand.

Zoning puts the control in the hands of the user (homeowner) via the thermostats.  These thermostats can be set to optimize energy savings or comfort... or, most likely, somewhere in between.

Some believe the primary purpose of zoning is comfort & I would agree, but, SmartZone can be used in some applications to save energy by reducing necessary run-time.

As far as I have found there have been very few and NO independent studies on the energy savings capabilities of hvac zone control but I have personally been in the industry for 14 years and I believe I know why.  Every test I have seen is try to prove some % of energy savings and yet there is a flaw with even the question that is being asked.  The problem with this question is that it is looking for an automatic percentage saving when zoning is installed.  I think this gets to the heart of why the professionals that dispute zone control's ability to "save energy" do so. 

This is an IMPORTANT NOTE:  HVAC Zone Control by itself will NOT save energy.  However, it CAN be used to save energy.

A proper study to prove that zone control CAN save energy would be straight-forward.   Two identical houses with identical hvac systems, one with a 2 zone system & the other with a single thermostat.  On the house with zoning, set one thermostat to OFF 12 hours per day and the other thermostat to run a normal 24hr / 7 day schedule.  The thermostat schedule should be the same as the 24hr / 7 day schedule in the house with only one thermostat.  This study would show that zoning can save energy if used in certain ways.

SmartZone has been around since 2004 and we have over 200,000 installed in the field.  We have seen direct feedback that empirically shows energy savings, not just in isolated cases but in extremely high volume.  First hand, real-world experience shows that it can be done, but it also shows that in cases where comfort is the priority... energy savings isn't a guarantee with zone control.

Check out SmartZone at ZoningSupply.com

SmartZone-4X
Sale Price:$229.99 Original Price:$299.00
Quantity:
Add To Cart
 

 

 

NEW to ZoningSupply - Insertable (Retrofit) Dampers

HVAC Contractors, Productszoning supplyComment

We are proud to announce the continuation of our damper product line here at ZoningSupply.com with the "Insert-able" damper.

Ecojay SmartZone Slip-in insertable damper

Some applications call for dampers that can be "slipped" into round duct that is spiral or other hard pipe style duct.  This is not intended for use with flex-duct but can be used with any other type of hard duct.  Simply cut a slit in the duct, insert the damper and screw it down.

Ecojay SmartZone Insertable Damper
PRO-Grade Insert Zone Damper (Retrofit)
from $99.99

4", 5", 6", 7", 8", 9", 10" ROUND Diameter Dampers

12” & 14” Diameter insert dampers require additional hole to be drilled in duct opposite damper. (grommet included to insert shaft)

FEATURES:
Industry-leading quality & highest reliability, Belimo Motor, Full-seal gasket blade, makes mounting in any round duct easy with these super-heavy duty retro-fit slip-in dampers

NOTE: All dampers subject to a 10% restocking fee.
 

Diameter:
Quantity:
Add To Cart

SmartZone is great for fireplace season... no more cold areas.

homeowners, Other HVACzoning supplyComment

Most people enjoy a good crackling fireplace when it's cold and snowy during the winter months even it isn't the primary source of heat for our homes these days... at least for most of us.  One problem that is common with homes that only have a single thermostat (no zoning) is that when a fire is burning, areas away from the fire get colder than the rest of the house.  Zone control can be the perfect solution...

Air balancing information & IOT evaluation from ContractingBusiness

Other HVAC, HVAC Contractorszoning supplyComment

Good articles that can affect HVAC zone control

If your technicians aren’t checking system airflow on every service call, you’re doing your company and your customers a disservice. Air balancing is the missing link in getting residential HVAC systems to perform at or near their peak levels.
— ContractingBusiness.com

Photo by scyther5/iStock / Getty Images
It is easy to be confused when it comes to the Internet of Things (IoT), with so many products and objects being connected and made more intelligent. It sounds overly complex, but one application that is easy to understand is HVAC IoT.

HVAC IoT is made up of a system of smart thermostats placed throughout building zones. The devices, and therefore the zones, are connected over wireless and software and work together as one brain. The brain has a nervous system with sensor endings in every room, hallway or lobby to monitor any environmental changes that could prompt the HVAC system to react
— ContractingBusiness.com

HVAC Contractors: Out-Perform the Competition with ZoningSupply.com

Other HVAC, HVAC Contractors, HVAC Industry, ZoningSupplyWhitney PitzerComment

Contractors nowadays are finding that homeowners and business-owners are looking for all the bells and whistles they can reasonably afford and install. Among features like energy-efficient fixtures and home-automation, HVAC zoning is usually near the top of this list. Of course, zoning offers multiple benefits to homes and buildings as it can save energy and provide a custom level of comfort.

As HVAC zoning rises in popularity, homeowners and business-owners are beginning to ask for it by name.

How can contractors make the most of this movement?
It starts with choices. Many contractors have unfortunately limited themselves to zone control systems that sit at the top of the market (as well as the top of the price-range.) This would be great if these “name-brand” zoning systems offered quality, reliability and features that justified the price. This is simply not the case. Contractors who have worked with zoning for a while can attest to this. The good news is that there are now many choices when it comes to zone controls, dampers, and equipment. Contractors and suppliers can now sift through the choices and figure out which systems are the simplest to install, the most reliable, and provide the best customer support.

This is where ZoningSupply.com comes in. ZoningSupply guarantees their products to be the most reliable, the easiest to install, and the most affordable in the marketplace. Hundreds of contractor and homeowner testimonials over the past 10+ years sing praises of the top-notch products they offer.
Here’s why . . .

Contractor-Friendly
The engineers behind ZoningSupply products will tell you that their systems were designed with the contractor in mind. In other words, full-color install guides, screwless wiring, and color-coded LEDs are only the start. If a contractor picks up the phone and talks to Jeff or one of our other tech-support specialists, they’ll be sure to have all of their questions answered quickly but thoroughly.  

Easy-to-follow instructions and simple design make for a lightning-fast install.  

Ship Direct for Free
Furthermore, ZoningSupply.com can ship anywhere in the U.S. for free. Individual components or entire systems can be purchased on the website and delivered straight to your office or job site,  

Affordable
ZoningSupply’s featured SmartZone 2x, 4x, and 2L systems are among the most affordable in the marketplace. This puts money in your pocket and provides savings that can be passed along to homeowners.

Universally Compatible
If a contractor uses ZoningSupply, they can confidently offer retrofit options for virtually any existing HVAC system on the market. This means not having to learn and re-learn various installation procedures. This also means that nearly every home or building in your area can be retrofitted for zoning . . . Think of the opportunities!

With zone control systems, as with any product, there are the good, the bad, and the ugly. In the end, they all must answer to the contractors and ultimately the homeowners. When bidding on projects or marketing their services, contractors should equip themselves with the confidence and reliability that ZoningSupply.com products provide.  

More unbiased Zone control discusson on homeenergy

Other HVACzoning supplyComment

-------------------------------------------
QUESSTION by
Adam Zielinski

Homeowners with forced air duct systems always want to close the registers in rooms they aren't using, and close the doors to those rooms, in the belief that doing so will save energy and money.
I always thought doing this was over-rated and unlikely to save a significant amount of energy or money.  I could see doing it for one or two rooms perhaps, but sometimes homeowners close off half of their house or more.
This creates unbalanced air flow in the duct system and likely results in over heating the furnace heat exchanger, and or short cycling the furnace.  So the furnace spends a lot of time in start up mode and less time at peak efficiency.
I have not seen any real studies done on this however.  I'd like to see some data or research on this.

Reply by dale conner
Adam, most furnaces will move the proper amount of air through the blower and heat exchanger if the furnace cabinet pressure doesnt exceed .5 IWC and the furnace capacity was chosen based on a manual J calculation. This information can be found in the furnace installation manual or IOM (installation,operation,maintenance) that comes with a new furnace. However, this does not mean we are getting adequate air delivery to all of the rooms in the house due to excessive air leakage in the ducts and/or incorrect duct lengths or diameters routed to each room.

-----------------------------------------
QUESTION by Judi Lyall

How about using a motorized damper ?

Reply by dale conner
A single motorized damper can be used to control a zoned area but you also have to install a barometric by-pass damper to prevent over pressurization
www.zoningsupply.com

-----------------------------------------

See full discussion: http://homeenergypros.lbl.gov/group/hvac/forum/topic/show?id=6069565%3ATopic%3A7207